Summary for Test 2024-01-04-55-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date01/04/2024 Sample Unique Key55
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/04/2024
Sample typeQuality Control A brief description of the sampleQC Sampling Data
The quantity of what the sample constitutes26CY From where was the sample collectedSource
First name of sampler or witnessed byConnor Last name of sampler or witnessed byPelan
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKIE-CON, INC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberK5070-4212
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected120442
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-04-55
DIME Test ID: 2024-01-04-55-1
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-05-16

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Connor Pelan
Date of test: 01/05/2024
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Average cylinder density (to nearest 1 pcf): 0 lb/ft^3
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): Transfer strength of 5,160psi

Test was verified on 5/16/2024