Summary for Test 2024-05-02-41-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1000330 DEA: 024H0804 EFIS: 0218000075 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96-R0/R16 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Somes Bar CAPM |
| Location Description | In Siskiyou County at and near Somes Bar from Humboldt County Line to 0.1 mile west of Dillon Creek Bridge |
| QA Service Level | 1 (Verified on 05/09/2024) |
Sample Information
| Sample Taken Date | 05/02/2024 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/02/2024 |
| Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation, C-3 |
| The quantity of what the sample constitutes | 1 container for culvert recommendation C-3 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Steiner |
| Title of sampler | ADME | Telephone number of sampler | |
| Laboratory sample identification | D79498 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 847471 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SIS-96-6.30 RT SH @ INLET | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-05-02-41
DIME Test ID: 2024-05-02-41-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-05-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 05/13/2024
Minimum soil resistance of the lab measurement: 5350 Ohms
Soil sample temperature: 20.1 C
Soil box constant: 1
pH of soil: 6.11
Minimum soil resistance corrected to 15.5: 5965.25 Ohm-cm
Minimum soil resistivity at 15.5: 5965 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.11, p=5965.Ω∙cm
Test was verified on 5/20/2024 ✔