Summary for Test 2024-04-15-76-2
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 994325 DEA: 044J4904 EFIS: 0415000356 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-13-6.7/7.2 |
| Award Date | 01/09/2023 |
| Closeout Date | 11/27/2024 |
| Work Description | CONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY. |
| Location Description | ALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
| Sample Taken Date | 04/15/2024 | Sample Unique Key | 76 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH RHMA-G |
| The quantity of what the sample constitutes | 8225Grams | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | HALL |
| Title of sampler | Lab Technician | Telephone number of sampler | 7072999133 |
| Laboratory sample identification | Con_24_210 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | De Silva Gates Sunol Drier Drum Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0007 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | belt stream @ plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | 1 | |
| Sublot number | 2 | Aggregate Mix Number | MD 6668 |
Test Details
DIME Sample ID: 2024-04-15-76
DIME Test ID: 2024-04-15-76-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-05-15
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 04/16/2024
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 98 % | ||||||
| 87 % | ||||||
| 38 % | ||||||
| 14 % | ||||||
| 9 % | ||||||
| 6 % | ||||||
| 5 % | ||||||
| 3 % | ||||||
| 2.6 % | ||||||
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 2
De Silva Gates Sunol Drier Drum Plant
Test was verified on 5/15/2024 ✔