Summary for Test 2024-05-06-33-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994872
DEA: 060X1604
EFIS: 0618000183
DIST-CO-RTE-PM06-KER-58-R64.4/67.3
Award Date08/29/2023
Closeout Date05/09/2025
Work DescriptionHMA (TYPE A), RHMA-G, JPCP, CRCP & HIGH SPEED WEIGH-IN-MOTION SYSTEM.
Location DescriptionKERN COUNTY NEAR EDISON FROM 0.2 MILE WEST OF TEJON HIGHWAY OVERCROSSING TO CALIENTE CREEK BRIDGE
QA Service Level1 (Verified on 06/14/2023)

Sample Information

Sample Taken Date05/06/2024 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing05/10/2024 Sample typeDepartment Acceptance
A brief description of the sample3/4" MIX HMA-TACK COAT The quantity of what the sample constitutes1 jar
From where was the sample collectedJob Site First name of sampler or witnessed byPaul
Last name of sampler or witnessed byKlinker Title of samplerMaterial Tester
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVSS Emultech
Transportation Laboratory (TL) Number772726 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2024-05-06-33
DIME Test ID: 2024-05-06-33-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-05-13

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 05/13/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 137.6 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 122.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 138.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 122.3 g
Beaker 1 Residue: 30.4 %
Beaker 2 Residue: 32.2 %
Percentage of residue: 31 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 5/13/2024 ✔