Summary for Test 2024-04-24-65-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994745 DEA: 040Y2304 EFIS: 0422000258 |
---|---|
DIST-CO-RTE-PM | 04-NAP-29-0.0/5.1 |
Award Date | 03/08/2023 |
Closeout Date | 01/10/2024 |
Work Description | Cold plane AC pavement and place HMA (A). |
Location Description | CONSTRUCTION ON STATE HIGHWAY IN NAPA COUNTY IN AND NEAR AMERICAN CANYON FROM SOLANO COUNTY LINE TO 0.4 MILE NORTH OF AIRPORT BOULEVARD. |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 04/24/2024 | Sample Unique Key | 65 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/26/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4-INCH HMA Type A and B |
The quantity of what the sample constitutes | 2476 Grams | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | HALL |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Con_24_187 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Vallejo Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 22091W |
Test Details
DIME Sample ID: 2024-04-24-65
DIME Test ID: 2024-04-24-65-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-13
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 04/26/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2219.2 g
Mass Loss: 188.7 g
Correction Factor (Percent by mass of HMA Specimen): 1.67 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.08 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.87 %
General comments (publicly viewable) (Max 1000 characters): Sample 1 of the day
Vulcan Vallejo Batch Plant
Test was verified on 5/13/2024 ✔