Summary for Test 2024-04-24-65-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994745
DEA: 040Y2304
EFIS: 0422000258
DIST-CO-RTE-PM04-NAP-29-0.0/5.1
Award Date03/08/2023
Closeout Date01/10/2024
Work DescriptionCold plane AC pavement and place HMA (A).
Location DescriptionCONSTRUCTION ON STATE HIGHWAY IN NAPA COUNTY IN AND NEAR AMERICAN CANYON FROM SOLANO COUNTY LINE TO 0.4 MILE NORTH OF AIRPORT BOULEVARD.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date04/24/2024 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2024
Sample typeQuality Assurance A brief description of the sample3/4-INCH HMA Type A and B
The quantity of what the sample constitutes2476 Grams From where was the sample collectedSupplier
First name of sampler or witnessed byNick Last name of sampler or witnessed byHALL
Title of sampler Telephone number of sampler7072999133
Laboratory sample identificationCon_24_187 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number22091W

Test Details

DIME Sample ID: 2024-04-24-65
DIME Test ID: 2024-04-24-65-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-13

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 04/26/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2219.2 g
Mass Loss: 188.7 g
Correction Factor (Percent by mass of HMA Specimen): 1.67 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.08 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.87 %
General comments (publicly viewable) (Max 1000 characters): Sample 1 of the day Vulcan Vallejo Batch Plant

Test was verified on 5/13/2024