Summary for Test 2024-05-10-3-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994819 DEA: 060U4304 EFIS: 0616000033 |
---|---|
DIST-CO-RTE-PM | 06-KER-184-8.5/11.6 |
Award Date | 10/26/2023 |
Closeout Date | Not set |
Work Description | RESURFACE LANES AND SHOULDERS. |
Location Description | KERN COUNTY IN AND NEAR BAKERSFIELD FROM 0.1 MILE NORTH OF EDISON HIGHWAY TO 0.1 MILE NORTH OF CHASE AVENUE |
QA Service Level | 1 (Verified on 05/22/2023) |
Sample Information
Sample Taken Date | 05/10/2024 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/10/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA type A |
The quantity of what the sample constitutes | 10 boxes HMA type A, 2 bags of aggregate | From where was the sample collected | Source |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Klinker |
Title of sampler | Material Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 7 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-05-10-3
DIME Test ID: 2024-05-10-3-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-10
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 05/10/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3865.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6007.3 g
Mass of HMA Sample prior to ignition: 2141.4 g
Mass Loss: 107.4 g
Mass of aggregate remaining after ignition: 2034.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.58 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-0U4304_37038_240510_L1SL7_T308_HMA | 103.97 KB | 05/10/2024 | 2024-05-10-3-1 | Info |
Test was verified on 5/10/2024 ✔