Summary for Test 2024-04-26-19-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994328
DEA: 081H0604
EFIS: 0816000130
DIST-CO-RTE-PM08-RIV-74-34.3/45.1
Award Date04/03/2023
Closeout Date08/26/2025
Work DescriptionFIBER OPTIC CABLE SYSTEMS, RHMA, HMA, AND MINOR CONCRETE.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR HEMET FROM WINCHESTER ROAD TO FAIRVIEW AVENUE
QA Service Level1 (Verified on 08/28/2023)

Sample Information

Sample Taken Date04/26/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/03/2024
Sample typeDepartment Acceptance A brief description of the sample3/4" HMA-A-SP R15
The quantity of what the sample constitutes2 BOXES OF HMA, 1QT OIL, 1 BAG RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byALBERTO Last name of sampler or witnessed byPINEDA- GONZALEZ
Title of sampler Telephone number of sampler
Laboratory sample identification0219A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt - Perris Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105927
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-04-26-19
DIME Test ID: 2024-04-26-19-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-10

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 05/09/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2174.3 g
Mass Loss: 99.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.28 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.06 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.31 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/10/2024