Summary for Test 2024-04-03-94-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/03/2024 Sample Unique Key94
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/06/2024
Sample typeVerification A brief description of the sampleTank 10027
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byGustavo Last name of sampler or witnessed byMoreno
Title of sampler Telephone number of sampler
Laboratory sample identification040324-011 Linked DIME Sample ID2024-04-03-46
The fabricator/manufacturer/facility nameSouth Gate, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-04-03-94
DIME Test ID: 2024-04-03-94-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-05-09

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 05/09/2024
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 58.088 kPa
Phase Angle (δ) (for the 10 cycles): 45.3 degree
Complex Modulus (G*) (for the 10 measurements): 5779.638 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 4108 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 5/9/2024