Summary for Test 2024-05-06-23-2
Test performed: AASHTO T335-09r13Project Information
| Project Identifiers | Project ID: 993811 DEA: 11422304 EFIS: 1115000180 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-78-0.3/R16.0 |
| Award Date | 10/28/2022 |
| Closeout Date | 06/09/2025 |
| Work Description | CULVERT REPAIRS, COLD PLANE, RHMA-G, MODIFY LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 78/5 SEPARATION TO 0.5 MILE WEST OF ROUTE 15/78 SEPARATION |
| QA Service Level | 1 (Verified on 06/13/2022) |
Sample Information
| Sample Taken Date | 05/06/2024 | Sample Unique Key | 23 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/07/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" RHMA-PSU |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0501-PSU | Linked DIME Sample ID | 2024-05-06-22 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-05-06-23
DIME Test ID: 2024-05-06-23-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2024-05-21
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 2 Faced
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 05/10/2024
Mass of fractured, coarse, 2 faced particles tested: 1000 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 0 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters): complies
Test was verified on 5/21/2024 ✔