Summary for Test 2024-05-08-6-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-99-R4.9/11.6 |
| Award Date | 02/25/2021 |
| Closeout Date | 12/02/2025 |
| Work Description | CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION. |
| Location Description | FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
| Sample Taken Date | 05/08/2024 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/08/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA Type A | The quantity of what the sample constitutes | 0-750 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Noah |
| Last name of sampler or witnessed by | Hunt | Title of sampler | Senior Materials Tester |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Sanger | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 17 |
| Sublot number | 5 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-05-08-6
DIME Test ID: 2024-05-08-6-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-09
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 05/08/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 2887.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5011.3 g
Mass of HMA Sample prior to ignition: 2123.6 g
Mass Loss: 114.8 g
Mass of aggregate remaining after ignition: 2008.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.11 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.17 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/9/2024 ✔