Summary for Test 2024-04-20-5-8
Test performed: AASHTO T84-14Project Information
| Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for storing JMF sample data |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/20/2024 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2024 |
| Sample type | Verification | A brief description of the sample | Aggregate |
| The quantity of what the sample constitutes | 12 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Glenn | Last name of sampler or witnessed by | Bradley |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Teichert - Grantline | Transportation Laboratory (TL) Number | Not set |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-34-0047 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
| The plant number | Not set | A detailed description of where the material sample was collected | HMA Plant |
| Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2024-04-20-5
DIME Test ID: 2024-04-20-5-8
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-05-08
Test Results
Input Type: Measured
Tester's full name: Aristeo Flores
Date of test: 05/03/2024
Mass of saturated surface dry sample (before pycnometer) (S): 508.7 grams
Mass of the pycnometer with water and aggregate (C): 991.8 grams
Mass of the pycnometer with water (B): 673.0 grams
Mass of the oven dried sample (before pycnometer) (A): 498.0 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 508.7 grams
Mass of the oven dry aggregate (for absorption) (A): 498.0 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.622
Bulk specific gravity (SSD Basis): 2.679
Apparent specific gravity: 2.779
Absorption: 2.1 %
General comments (publicly viewable) (Max 1000 characters): Bulk specific gravity (SSD) of fine aggregate, Bulk specific gravity of fine aggregate,
Apparent specific gravity of fine aggregate, Apparent specific gravity of supplemental fines, Absorption of fine aggregate
Test was verified on 5/8/2024 ✔