Summary for Test 2024-05-06-3-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 995263 DEA: 061G3304 EFIS: 0624000029 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-118/138 |
Award Date | 08/18/2023 |
Closeout Date | Not set |
Work Description | FRE 180 Emergency Slope Repairs. |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/20/2023) |
Sample Information
Sample Taken Date | 05/06/2024 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/07/2024 |
Sample type | Department Acceptance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 265 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Gurjeet | Last name of sampler or witnessed by | Litt |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | vulcan materials Ashlan | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 1 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-05-06-3
DIME Test ID: 2024-05-06-3-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-08
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 05/06/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 2874.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 4940.3 g
Mass of HMA Sample prior to ignition: 2065.6 g
Mass Loss: 95.3 g
Mass of aggregate remaining after ignition: 1970.3 g
Correction Factor (Percent by mass of HMA Specimen): -0.14 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.60 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2024 ✔