Summary for Test 2024-04-10-81-1
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 994321 DEA: 040K1604 EFIS: 0416000044 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,CC-80-R7.6/8.0,0.0/13.5 |
| Award Date | 02/08/2023 |
| Closeout Date | 09/14/2026 |
| Work Description | CONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER. |
| Location Description | ALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET |
| QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
| Sample Taken Date | 04/10/2024 | Sample Unique Key | 81 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/10/2024 | Sample type | Independent Assurance |
| A brief description of the sample | Class 2 AB Recycled | The quantity of what the sample constitutes | 2 containers |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | IGNACIO |
| Last name of sampler or witnessed by | ARECHIGA | Title of sampler | |
| Telephone number of sampler | 5102077252 | Laboratory sample identification | Rich_24_024 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Vallejo | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Job site | |
| Where the material sample would have been placed if not sampled | Yes |
Test Details
DIME Sample ID: 2024-04-10-81
DIME Test ID: 2024-04-10-81-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-05-07
Test Results
Is oversize material: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/10/2024
In-place wet density: 2.20
Highest adjust wet density: 2.21
% Moisture: 12.0 %
Optimum Moisture: 14.0 %
Relative compaction: 100
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2024 ✔