Summary for Test 2024-04-08-35-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 994311
DEA: 080R1704
EFIS: 0812000028
DIST-CO-RTE-PM08-SBD-40-R25.0/R50.0
Award Date12/01/2022
Closeout DateNot set
Work DescriptionCONSTRUCT CSP, CSPA, SSPPA, STR CONC HW, IB, BFM, RSP, & MGS.
Location DescriptionSAN BERNARDINO COUNTY AT NEWBERRY SPRINGS AND LUDLOW FROM 1.6 MILES EAST OF FORT CADY ROAD OVERCROSSING TO CRUCERO ROAD UNDERCROSSING
QA Service Level1 (Verified on 07/28/2023)

Sample Information

Sample Taken Date04/08/2024 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/09/2024
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byFernando Last name of sampler or witnessed byCarranza
Title of samplerQA Atlas Telephone number of sampler
Laboratory sample identification1060-48 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertson Transportation Laboratory (TL) Number1060-48
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSM450P48
The truck number from where the sample was collected2225 The batch plant ticket number from where the sample was collected572116
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedI40 Near Hector Road DS 17 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-04-08-35
DIME Test ID: 2024-04-08-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-05-06

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/15/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 105880 lb
Maximum load on cylinder 2: 110990 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 3795.0 psi
Compressive strength of cylinder 2: 3951.2 psi
Compressive strength (to nearest 10 psi): 3870 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/6/2024