Summary for Test 2024-04-16-58-2
Test performed: ASTM D217-16Project Information
| Project Identifiers | Project ID: 995232 DEA: 120U1704 EFIS: 1223000051 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-133,261-9.8/12.6,0.0/3.5 |
| Award Date | 12/27/2023 |
| Closeout Date | 09/20/2024 |
| Work Description | COLD PLANE, OVERLAY, AND REFRESH PAVEMENT DELINEATION. |
| Location Description | ORANGE COUNTY IN IRVINE ON ROUTE 133 FROM TECHNOLOGY DRIVE UNDERCROSSING TO PORTOLA PARKWAY UNDERCROSSING AND ON ROUTE 261 FROM WALNUT AVENUE OVERCROSSING TO 0.6 MILE NORTH OF PORTOLA PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 10/16/2023) |
Sample Information
| Sample Taken Date | 04/16/2024 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/23/2024 |
| Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Cuong | Last name of sampler or witnessed by | Pham |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | AAA-Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2024-04-16-58
DIME Test ID: 2024-04-16-58-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2024-05-08
Test Results
Determination: Unworked Penetration
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 05/02/2024
Unworked Penetration: 25 0.1 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2024 ✔