Summary for Test 2024-04-15-38-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993153
DEA: 120H0474
EFIS: 1212000053
DIST-CO-RTE-PM12-ORA-241-27.8/38.0
Award Date10/21/2021
Closeout Date06/18/2025
Work DescriptionPLACE HMA AND PERFORATED PLASTIC PIPE UNDERDRAIN.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF ROUTE 133 TO 0.5 MILE SOUTH OF ROUTE 91
QA Service Level1 (Verified on 08/02/2021)

Sample Information

Sample Taken Date04/15/2024 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2024
Sample typeVerification A brief description of the samplePSU 3/4" WMA-A-SP R25 0.25EVO PG64-10
The quantity of what the sample constitutes4 Bags of Agg., 1 Bag of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed byNguyen
Title of sampler Telephone number of sampler
Laboratory sample identification0181A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Corona/ Fish Canyon-IRW/ SJR/ Ingevity Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027, 91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedVulcan - Corona Drum
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number220200W CORD SJR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-15-38
DIME Test ID: 2024-04-15-38-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-05-15

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 04/23/2024
Mass of saturated surface dry sample (before pycnometer) (S): 500.0 grams
Mass of the pycnometer with water and aggregate (C): 967.3 grams
Mass of the pycnometer with water (B): 653.8 grams
Mass of the oven dried sample (before pycnometer) (A): 493.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.0 grams
Mass of the oven dry aggregate (for absorption) (A): 493.8 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.648
Bulk specific gravity (SSD Basis): 2.681
Apparent specific gravity: 2.739
Absorption: 1.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/15/2024