Summary for Test 2024-05-01-41-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
---|---|
DIST-CO-RTE-PM | 07-LA-14-60.70 |
Award Date | 02/07/2023 |
Closeout Date | Not set |
Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
Sample Taken Date | 05/01/2024 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/01/2024 |
Sample type | Quality Assurance | A brief description of the sample | Native Soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Manuel | Last name of sampler or witnessed by | Uy |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 24-0848 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-05-01-41
DIME Test ID: 2024-05-01-41-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-05-02
Test Results
Method Type:: Direct Read
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Manuel Uy
Date of test: 05/01/2024
Gage No.: no data
Test No.: no data
Nuclear By: no data
Non-Bias Plan No.: no data
Depth: no data
Material No.: no data
Material Type: no data
Impact By: no data
Standard Count Density: 2995 g/cc
Count or Density 1: 3451 g/cc
Count or Density 2: 3710 g/cc
Count or Density 3: 3725 g/cc
Count or Density 4: 3573 g/cc
Count or Density 5: 3497 g/cc
Standard Count Moisture: 1069 g/cc
Moisture Count 1: 296 g/cc
Moisture Count 2: 290 g/cc
Moisture Count 3: 314 g/cc
Moisture Count 4: 302 g/cc
Moisture Count 5: 307 g/cc
Sum of Count or Density: 17956.00 g/cc
Average of Count or Density: 3591.20 g/cc
Sum of Moisture Count: 1509.00 g/cc
Average of Moisture Count: 301.80 g/cc
Calculated Percent Relative Compaction: 97.1 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/2/2024 ✔