Summary for Test 2024-04-13-1-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 994903 DEA: 11430244 EFIS: 1118000033 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-125-9.3/13.0 |
| Award Date | 09/06/2023 |
| Closeout Date | Not set |
| Work Description | PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK. |
| Location Description | SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION |
| QA Service Level | 1 (Verified on 11/14/2023) |
Sample Information
| Sample Taken Date | 04/13/2024 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0109-PSU | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220817 Otay Val | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-04-13-1
DIME Test ID: 2024-04-13-1-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2024-05-14
Test Results
Unit system used?: SI Units
Input Type: Measured
Tester's full name: Joseph Seymour
Date of test: 04/24/2024
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
| 150.0 mm | 15.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | |
| 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | |
| 3834.9 g | 3834.7 g | 3834.2 g | 3834.4 g | 3834.1 g | 3834.6 g | |
| 2231.7 g | 2231.4 g | 2231.2 g | 2231.1 g | 2231.3 g | 2231.2 g | |
| 3858.8 g | 3858.6 g | 3858.1 g | 3858.2 g | 3858.4 g | 3858.6 g | |
| 2.520 | 2.520 | 2.520 | 2.520 | 2.520 | 2.520 | |
| 3910.0 g | 3916.2 g | 3915.6 g | ||||
| 2231.7 g | 2231.4 g | 2231.2 g | ||||
| 95.1 mm | 95.1 mm | 95.1 mm | ||||
| 89 mmHg | 97 mmHg | 87 mmHg | ||||
| 0 inHg | 0 inHg | 0 inHg | ||||
| 5 minutes | 5 minutes | 5 minutes | ||||
1627.1 cm^3 | 1627.2 cm^3 | 1626.9 cm^3 | 1627.1 cm^3 | 1627.1 cm^3 | 1627.4 cm^3 | |
2.357 | 2.357 | 2.357 | 2.357 | 2.356 | 2.356 | |
6.5 % | 6.5 % | 6.5 % | 6.5 % | 6.5 % | 6.5 % | |
105.8 cm^3 | 105.8 cm^3 | 105.7 cm^3 | 105.8 cm^3 | 105.8 cm^3 | 105.8 cm^3 | |
3909.0 g | 3908.8 g | 3908.2 g | ||||
3919.5 g | 3919.3 g | 3918.8 g | ||||
1678.3 cm^3 | 1684.8 cm^3 | 1684.4 cm^3 | ||||
75.1 cm^3 | 81.5 cm^3 | 81.4 cm^3 | ||||
71 % | 77 % | 77 % | ||||
3.1 % | 3.5 % | 3.5 % | ||||
18594 N | 15211 N | 19609 N | 34904 N | 29616 N | 31549 N | |
2 | 2 | 2 | 2 | 2 | 2 | |
2 | 2 | 2 | 2 | 2 | 2 | |
2 | 2 | 2 | 2 | 2 | 2 | |
830 kPa | 6788 kPa | 875 kPa | 1559 kPa | 1323 kPa | 1409 kPa | |
410 psi | 207 psi | |||||
1.98 | ||||||
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 5/14/2024 ✔