Summary for Test 2024-04-30-19-2
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 994781 DEA: 07322704 EFIS: 0716000067 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-1-1.3/26.6 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT PERVIOUS CONCRETE PAVEMENT |
| Location Description | VENTURA COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/13/2023) |
Sample Information
| Sample Taken Date | 04/30/2024 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/30/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Aggregate Base |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
| First name of sampler or witnessed by | Kristopher | Last name of sampler or witnessed by | Martinez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 24-0839 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-04-30-19
DIME Test ID: 2024-04-30-19-2
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-05-01
Test Results
Is oversize material: No
Input Type: Measured
Tester's full name: Kristopher Martinez
Date of test: 04/30/2024
In-place wet density: 1.94
Highest adjust wet density: 2.10
% Moisture: no data
Optimum Moisture: no data
Relative compaction: 92
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/1/2024 ✔