Summary for Test 2024-04-10-74-7
Test performed: CTM 226-July 2010Project Information
Project Identifiers | Project ID: 215314 DEA: 07333004 EFIS: 0716000298 |
---|---|
DIST-CO-RTE-PM | 07-LA-5,5-15.1/22.9 |
Award Date | 10/20/2022 |
Closeout Date | Not set |
Work Description | PROJECT PILOT 1 |
Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES ON ROUTE 5 FROM 0.1 MILE SOUTH OF CALZONA STREET TO 0.1 MILE SOUTH OF RIVERSIDE DRIVE AND ROUTE 2 AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 04/10/2024 | Sample Unique Key | 74 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2024 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 PCC Aggregates |
The quantity of what the sample constitutes | 50 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National-Vernon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0052 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | Mix S63C451T1 | |
The plant number | vernon | A detailed description of where the material sample was collected | Stockpile @ Plant |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | S63C451T1 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-04-10-74
DIME Test ID: 2024-04-10-74-7
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2024-05-02
Test Results
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 04/15/2024
Wet weight of the sample: 1216.0000000000 grams
Dry weight of the sample: 1134.0000000000 grams
Weight of water in sample: 82.0000000000 grams
Percent moisture: 7.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/2/2024 ✔