Summary for Test 2017-05-24-7-4
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/24/2017 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/05/2017 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 9 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Daniel |
| Last name of sampler or witnessed by | Reyes | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | A M Nut and Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | B301-126-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3068594, 3066882, 3066144 | Nut Mfg. Lot Number(s) | 383997A, 385999A, 24298-6214105002 |
| Washer Mfg. Lot Number(s) | 2038077, 2014320, 2047508 | Bolt Specification | F1554 |
| Bolt Length(s) | 36", 18", 42" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1", 0.75", 1.5" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-05-24-7
DIME Test ID: 2017-05-24-7-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-06-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/08/2017
UTM: 400KIP
Temperature: 70 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | B30112617 | 1-8 HEX | 108990 | 484.8 | A194 | Fred |
General comments (publicly viewable) (Max 1000 characters): A194
Test Graph
Source: Partner Data Point FileTest was verified on 6/12/2017 ✔