Summary for Test 2024-03-25-9-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995083
DEA: 051R1604
EFIS: 0523000152
DIST-CO-RTE-PM05-SB-101-82.18, 82.2/82.2
Award DateNot set
Closeout DateNot set
Work DescriptionRepair high-load hit
Location DescriptionNear Santa Maria, US101 and Clark Ave overcrossing.
QA Service Level1 (Verified on 08/17/2023)

Sample Information

Sample Taken Date03/25/2024 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2024
Sample typeQuality Assurance A brief description of the sample#5 Zap Screwlok SL
The quantity of what the sample constitutes20 From where was the sample collectedJob Site
First name of sampler or witnessed byVICTOR Last name of sampler or witnessed byDELACRUZ
Title of samplerAssistant Structure Representative Telephone number of sampler8055712108
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTyler Reinforcing steel, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier51-0232
Structure nameClark Ave. OC

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelZap Screwlok SL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74131608 Rebar Heat Number(s)3800043812
Rebar Size 2 Coupler Unique IDSL-21-02

Test Details

DIME Sample ID: 2024-03-25-9
DIME Test ID: 2024-03-25-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-05-03

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 04/30/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 5/16mm1-0.00030.312617084418Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 5/3/2024