Summary for Test 2024-03-25-9-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 995083 DEA: 051R1604 EFIS: 0523000152 |
---|---|
DIST-CO-RTE-PM | 05-SB-101-82.18, 82.2/82.2 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Repair high-load hit |
Location Description | Near Santa Maria, US101 and Clark Ave overcrossing. |
QA Service Level | 1 (Verified on 08/17/2023) |
Sample Information
Sample Taken Date | 03/25/2024 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/29/2024 |
Sample type | Quality Assurance | A brief description of the sample | #5 Zap Screwlok SL |
The quantity of what the sample constitutes | 20 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | DELACRUZ |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | 8055712108 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Tyler Reinforcing steel, Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 51-0232 | |
Structure name | Clark Ave. OC |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | |
Rebar Size | #5 | Coupler Model | Zap Screwlok SL |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 74131608 | Rebar Heat Number(s) | 3800043812 |
Rebar Size 2 | Coupler Unique ID | SL-21-02 |
Test Details
DIME Sample ID: 2024-03-25-9
DIME Test ID: 2024-03-25-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-05-03
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 04/30/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 5/16mm | 1 | -0.0003 | 0.31 | 26170 | 84418 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 5/3/2024 ✔