Summary for Test 2024-04-22-41-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date04/22/2024 Sample Unique Key41
Date that the sample was received by the laboratory/organization performing the testing04/24/2024 Sample typeVerification
A brief description of the sampleJMF verification sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byJohn
Last name of sampler or witnessed byMejia Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-04-22-41
DIME Test ID: 2024-04-22-41-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-04-25

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 04/25/2024
Time of test: 9:40 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 51.8 %
Viscosity reading #1 (A) : 0.258 Pa-s
Viscosity reading #2 (B) : 0.259 Pa-s
Viscosity reading #3 (C): 0.259 Pa-s
Average viscosity: 0.259 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/25/2024