Summary for Test 2024-03-27-26-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 995519 DEA: 030L0804 EFIS: 0324000025 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-51-5.5/5.5 |
| Award Date | 07/14/2023 |
| Closeout Date | 03/21/2025 |
| Work Description | Bridge Rail Replacement due to Vehicle Strike |
| Location Description | Marconi Bridge |
| QA Service Level | 1 (Verified on 01/17/2024) |
Sample Information
| Sample Taken Date | 03/27/2024 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/29/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Cooley |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 114912 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT590133 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Unknown | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-03-27-26
DIME Test ID: 2024-03-27-26-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-04-24
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 04/24/2024
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 58309 lbf
Maximum load on cylinder 2: 65568 lbf
Maximum load on cylinder 3: 54858 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 4594.0 psi
Compressive strength of cylinder 2: 5192.0 psi
Compressive strength of cylinder 3: 4322.0 psi
Compressive strength (to nearest 10 psi): 4700 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 4/24/2024 ✔