Summary for Test 2024-04-10-67-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 993664
DEA: 073311U4
EFIS: 0719000098
DIST-CO-RTE-PM07-VEN-23,101-R3.3/R3.7,0.2/40.8
Award Date08/31/2022
Closeout DateNot set
Work DescriptionCONSTRUCT GUARDRAILS AND CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS, CAMARILLO, OXNARD AND VENTURA ON ROUTE 101 FROM THE LOS ANGELES /VENTURA COUNTY LINE TO OLD PACIFIC COAST HIGHWAY AND ON ROUTE 23 FROM ROUTE 23/101 SEPARATION TO HILLCREST DRIVE
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date04/10/2024 Sample Unique Key67
Date that the sample was received by the laboratory/organization performing the testing04/18/2024 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byEsteban
Last name of sampler or witnessed bySalgado Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-04-10-67
DIME Test ID: 2024-04-10-67-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-04-25

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Anthony Hernandez
Date of test: 04/22/2024
Time of test: 09:30 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 67.0 %
Viscosity reading #1 (A) : 0.333 Pa-s
Viscosity reading #2 (B) : 0.333 Pa-s
Viscosity reading #3 (C): 0.339 Pa-s
Average viscosity: 0.335 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/25/2024 ✔