Summary for Test 2024-04-11-37-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 995260
DEA: 061G0504
EFIS: 0623000195
DIST-CO-RTE-PM06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0
Award Date03/29/2023
Closeout DateNot set
Work DescriptionRoutes 180, 245 Emergency Slip Out Repair
Location DescriptionNot set
QA Service Level1 (Verified on 10/20/2023)

Sample Information

Sample Taken Date04/11/2024 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/12/2024
Sample typeQuality Assurance A brief description of the sampleConcrete Test Samples
The quantity of what the sample constitutes12 CY From where was the sample collectedJob Site
First name of sampler or witnessed byYe Last name of sampler or witnessed byYang
Title of samplerASR Telephone number of sampler559-779-0446
Laboratory sample identification148 Linked DIME Sample ID
The fabricator/manufacturer/facility nameOutback Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameWall 2 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number40F5G07
The truck number from where the sample was collected103 The batch plant ticket number from where the sample was collected157626
Concrete batch plantOutback Materials The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheelbarrow from concrete truck Where the material sample would have been placed if not sampledPile 2, 5
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-04-11-37
DIME Test ID: 2024-04-11-37-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-04-22

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 04/22/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 79240 lb
Maximum load on cylinder 2: 77370 lb
Maximum load on cylinder 3: 79390 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 11 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 6274.0 psi
Compressive strength of cylinder 2: 6125.9 psi
Compressive strength of cylinder 3: 6285.8 psi
Compressive strength (to nearest 10 psi): 6230 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/22/2024