Summary for Test 2023-06-26-104-3

Test performed: ASTM C1611-21
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 993815
DEA: 081C0814
EFIS: 0816000086
DIST-CO-RTE-PM08-RIV-10-R60.7/R74.3
Award Date03/28/2022
Closeout DateNot set
Work DescriptionI-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location DescriptionCoachella
QA Service Level1 (Verified on 05/03/2022)

Sample Information

Sample Taken Date06/26/2023 Sample Unique Key104
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/27/2023
Sample typeQuality Control A brief description of the sampleT-II/V Cement
The quantity of what the sample constitutes5.0 From where was the sample collectedManufacturer
First name of sampler or witnessed byMauril Last name of sampler or witnessed byMariano
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConFab California, LLC Shafter Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC_S8.5-0FG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3599
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from wheelbarrow collected from chute of ready mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-06-26-104
DIME Test ID: 2023-06-26-104-3
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Test Release Date: 2024-06-10

Test Results


What unit system is used for measurements?: inches
Input Type: Calculated
Tester's full name: Mauril Mariano
Date of test: 06/26/2023
Filling the mold procedure: Filling Procedure B (Inverted Mold)
Diameter 1: 25 in
Diameter 2: 25 in
Visual Stability Index: 0
Slump Flow: 25 in
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/10/2024

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.