Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993529
DEA: 11430514
EFIS: 1119000008
DIST-CO-RTE-PM11-SD-15-R31.3/R37.1
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCRCP, FIBER OPTIC CABLE, AND HMA.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
QA Service Level1 (Verified on 02/07/2022)

Sample Information

Sample Taken Date04/11/2024 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/12/2024
Sample typeQuality Assurance A brief description of the sample3/4" HMA PSU
The quantity of what the sample constitutes3 Bags From where was the sample collectedSource
First name of sampler or witnessed byBen Last name of sampler or witnessed bySmith
Title of sampler Telephone number of sampler
Laboratory sample identification6638-PSU Linked DIME Sample ID2024-04-11-40
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-11-41
DIME Test ID: 2024-04-11-41-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-04-22

Test Results


Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 04/18/2024
Mass of saturated surface dry sample (before pycnometer) (S): 500.2 grams
Mass of the pycnometer with water and aggregate (C): 986.4 grams
Mass of the pycnometer with water (B): 680.3 grams
Mass of the oven dried sample (before pycnometer) (A): 487.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.2 grams
Mass of the oven dry aggregate (for absorption) (A): 487.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.514
Bulk specific gravity (SSD Basis): 2.577
Apparent specific gravity: 2.684
Absorption: 2.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/22/2024