Summary for Test 2017-05-19-3-3
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 208714 DEA: 08043514 EFIS: 0800000010 |
---|---|
DIST-CO-RTE-PM | 08-SBD-58-R22.2/R31.1 |
Award Date | 12/30/2014 |
Closeout Date | 08/29/2018 |
Work Description | REALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY |
Location Description | HINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD. |
QA Service Level | 1 (Verified on 03/22/2013) |
Sample Information
Sample Taken Date | 05/19/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2017 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | ROBERT | Last name of sampler or witnessed by | BIRSBACH |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 915-519 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | ROBERTSONS | Transportation Laboratory (TL) Number | 20170519 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | RW1633 |
Structure name | RW 1633 |
Material Information
Material Type | Concrete | The concrete mix design number | SC90B38 |
---|---|---|---|
The truck number from where the sample was collected | 1228 | The batch plant ticket number from where the sample was collected | 2257089 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | chute | Where the material sample would have been placed if not sampled | RW 1633 STEM POUR 2 |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-05-19-3
DIME Test ID: 2017-05-19-3-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-06-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/24/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 93280 lb
Maximum load on cylinder 2: 93720 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 0.00
Age of specimen: 5 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3,277.6 psi
Compressive strength of cylinder 2: 3,293.0 psi
Compressive strength (to nearest 10 psi): 3290 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2017 ✔