Summary for Test 2024-04-15-26-2
Test performed: ASTM E18-20Project Information
| Project Identifiers | Project ID: 215349 DEA: 081C0824 EFIS: 0816000087 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-R104.9/R134.2 |
| Award Date | 03/24/2021 |
| Closeout Date | 01/06/2025 |
| Work Description | PLACE HMA (TYPE A), JPCP AND IMPORTED BORROW. |
| Location Description | RIVERSIDE COUNTY FROM ROUTE 10/177 SEPARATION TO 1.1 MILES WEST OF WILEY'S WELL RD OC |
| QA Service Level | 1 (Verified on 03/01/2021) |
Sample Information
| Sample Taken Date | 04/15/2024 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2024 |
| Sample type | Per Request | A brief description of the sample | #6 Rebar |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Julien | Last name of sampler or witnessed by | Atallah |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | na |
|---|---|---|---|
| Material Specification | N/A | Grade | na |
| Thickness | na | Shape | na |
| Metal Foundry Manufacturer (Mill) | na | Plate Dimension | na |
Test Details
DIME Sample ID: 2024-04-15-26
DIME Test ID: 2024-04-15-26-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2024-04-17
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 04/17/2024
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: no data
Finish Coating: Plain
Product Markings: 0
Size: 0
Bolt Length: 0
Hardness Reading Scale: B Scale
Spacing: Ok
Hardness Reading Average: 82.22
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2024 ✔