Summary for Test 2024-04-10-56-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 995230
DEA: 08496124
EFIS: 0816000145
DIST-CO-RTE-PM08---
Award Date01/17/2024
Closeout DateNot set
Work DescriptionFIBER OPTIC CABLE, RAMP METERING AND MODIFYING LIGHTING SYSTEMS.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR MORENO VALLEY FROM 0.3 MILE WEST OF PERRIS BOULEVARD UNDERCROSSING TO 0.4 MILE EAST OF GILMAN SPRINGS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/23/2023)

Sample Information

Sample Taken Date04/10/2024 Sample Unique Key56
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/10/2024
Sample typeDepartment Acceptance A brief description of the sampleClass 2 Aggregate Base
The quantity of what the sample constituteskg From where was the sample collectedJob Site
First name of sampler or witnessed byMilad Last name of sampler or witnessed byWarde
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedMVP #5 - Gilman Springs Rd just before SR-60 EB On-Ramp
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-04-10-56
DIME Test ID: 2024-04-10-56-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-16

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: Yes
Input Type: Calculated
Tester's full name: Milad Warde
Date of test: 04/10/2024
Sum of Count or Density: 3771.00 g/cc
Average of Count or Density: 1257.00 g/cc
Sum of Moisture Count: 228.00 g/cc
Average of Moisture Count: 76.00 g/cc
Count Ratio Density: 0.74
Count Ratio Moisture: 0.12
Calculated Percent Relative Compaction: 99.1 %
Reported Percent Relative Compaction: 99 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%

Test was verified on 4/16/2024