Summary for Test 2024-04-02-42-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 994352 DEA: 07352104 EFIS: 0718000213 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-138-43.8 |
| Award Date | 12/13/2022 |
| Closeout Date | 09/24/2024 |
| Work Description | INSTALL TRAFFIC SIGNAL SYSTEM AND UPGRADE CURB RAMPS. |
| Location Description | LOS ANGELES COUNTY IN PALMDALE AT SECOND STREET EAST. |
| QA Service Level | 1 (Verified on 01/25/2023) |
Sample Information
| Sample Taken Date | 04/02/2024 | Sample Unique Key | 42 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2024 |
| Sample type | Department Acceptance | A brief description of the sample | Aggregate Base |
| The quantity of what the sample constitutes | 46 cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Lou Ralph | Last name of sampler or witnessed by | Achuela |
| Title of sampler | TET | Telephone number of sampler | 2138170504 |
| Laboratory sample identification | 24-0568 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Aggregate Base |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | From various locations at Aggregate Base | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-04-02-42
DIME Test ID: 2024-04-02-42-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-12
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Lou Ralph Achuela
Date of test: 04/02/2024
Gage No.: 31104
Test No.: 1
Nuclear By: Lou Ralph Achuela
Non-Bias Plan No.: 2
Depth: 3''
Material No.: On-Site
Material Type: Aggregate Base
Impact By: Lou Ralph Achuela
Standard Count Density: 2026 g/cc
Count or Density 1: 2241 g/cc
Count or Density 2: 2099 g/cc
Count or Density 3: 2219 g/cc
Standard Count Moisture: 665 g/cc
Moisture Count 1: 80 g/cc
Moisture Count 2: 73 g/cc
Moisture Count 3: 65 g/cc
Sum of Count or Density: 6559 g/cc
Average of Count or Density: 2186 g/cc
Sum of Moisture Count: 218 g/cc
Average of Moisture Count: 73 g/cc
Count Ratio Density: 1.08
Count Ratio Moisture: 0.11
Calculated Percent Relative Compaction: 93 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/12/2024 ✔