Summary for Test 2024-03-14-58-3
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for storing JMF sample data |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/14/2024 | Sample Unique Key | 58 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2024 |
Sample type | Verification | A brief description of the sample | 2 bags of Combined RAP (1/2-inch) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
First name of sampler or witnessed by | Ward | Last name of sampler or witnessed by | Jenkins |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) — Latona Aggregates (Anderson, CA) | Transportation Laboratory (TL) Number | Not set |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt |
---|---|---|---|
Aggregate Size | Not set | Aggregate Source | Not set |
RAP Stockpile | Not set | Stockpile Size (tons) | Not set |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2024-03-14-58
DIME Test ID: 2024-03-14-58-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-04-12
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 03/21/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7334.2 grams
Mass of oven-dry sample in air for Sample 1: 1589.7 grams
Mass of container filled with the sample and water for Sample 1: 8304.9 grams
Temperature of Water: 76.8 °F
Specific Gravity for Sample 1: 2.568
Theoretical maximum density at 25°C (77°F): 2561 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.568,
Gser≈2.730
Test was verified on 4/12/2024 ✔