Summary for Test 2024-03-13-45-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
---|---|
DIST-CO-RTE-PM | 07-LA-14-60.70 |
Award Date | 02/07/2023 |
Closeout Date | Not set |
Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
Sample Taken Date | 03/13/2024 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2024 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A-SP R15 0.5% LAS |
The quantity of what the sample constitutes | 4 Bags of bin Aggs | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | Plant Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Materials - Palmdale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Various (see Notes) |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Bin | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-03-13-45
DIME Test ID: 2024-03-13-45-1
Testing Lab: CT D07 - Plant Services
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-04-17
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Avo Karajian
Date of test: 03/14/2024
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 88 %
Cumulative percent passing the 3/8 in. sieve: 80 %
Cumulative percent passing the #4 sieve: 56 %
Cumulative percent passing the #8 sieve: 40 %
Cumulative percent passing the #16 sieve: 28 %
Cumulative percent passing the #30 sieve: 19 %
Cumulative percent passing the #50 sieve: 11 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 2.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2024 ✔