Summary for Test 2024-04-07-4-7

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994612
DEA: 112N1414
EFIS: 1121000253
DIST-CO-RTE-PM11-SD-15,78-Various
Award Date05/26/2023
Closeout Date09/26/2024
Work DescriptionPLACE METHACRYLATE, POLYESTER CONCRETE, JOINT SEALS AND REPAIR SPALLS.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/22/2023)

Sample Information

Sample Taken Date04/07/2024 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing04/08/2024 Sample typeQuality Assurance
A brief description of the samplePSU The quantity of what the sample constitutes12 boxes
From where was the sample collectedSource First name of sampler or witnessed byBen
Last name of sampler or witnessed bySmith Title of sampler
Telephone number of sampler Laboratory sample identification0401-PSU
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21217005SR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-04-07-4
DIME Test ID: 2024-04-07-4-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-04-22

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Joseph Seymour/ DP. Smith
Date of test: 04/11/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3962.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5613.5 g
Mass of HMA Sample prior to ignition: 1650.9 g
Mass Loss: 168.7 g
Mass of aggregate remaining after ignition: 1482.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 295 C
Corrected Asphalt Binder Content: 10.22 %
General comments (publicly viewable) (Max 1000 characters): 3 RAP Burns

Test was verified on 4/22/2024 ✔