Summary for Test 2024-04-08-18-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 994321
DEA: 040K1604
EFIS: 0416000044
DIST-CO-RTE-PM04-ALA,CC-80-R7.6/8.0,0.0/13.5
Award Date02/08/2023
Closeout Date09/14/2026
Work DescriptionCONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER.
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date04/08/2024 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing04/08/2024 Sample typeQuality Assurance
A brief description of the sampleRecycle Class 2 Aggregate Base The quantity of what the sample constitutes19507 grams
From where was the sample collectedJob Site First name of sampler or witnessed byIGNACIO
Last name of sampler or witnessed byARECHIGA Title of samplerTET
Telephone number of sampler5102077252 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Vallejo
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleClass 2Aggregate Base
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedJob site
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-04-08-18
DIME Test ID: 2024-04-08-18-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-09

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/08/2024
Gage No.: 691
Test No.: Rich_24_021
Nuclear By: Jose Leon
Non-Bias Plan No.: 5
Depth: 8"
Material No.: Recycle Class 2 AB
Material Type: Base
Impact By: Ignacio Arechiga
Standard Count Density: 32258 g/cc
Count or Density 1: 27051 g/cc
Count or Density 2: 29776 g/cc
Count or Density 3: 25407 g/cc
Standard Count Moisture: 8627 g/cc
Moisture Count 1: 2668 g/cc
Moisture Count 2: 2515 g/cc
Moisture Count 3: 2648 g/cc
Sum of Count or Density: 82234 g/cc
Average of Count or Density: 27411 g/cc
Sum of Moisture Count: 7831 g/cc
Average of Moisture Count: 2610 g/cc
Count Ratio Density: 0.85
Count Ratio Moisture: 0.3
Calculated Percent Relative Compaction: 99.5 %
Reported Percent Relative Compaction: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/9/2024 ✔