Summary for Test 2024-04-08-18-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 994321
DEA: 040K1604
EFIS: 0416000044
DIST-CO-RTE-PM04-ALA,CC-80-R7.6/8.0,0.0/13.5
Award Date02/08/2023
Closeout Date09/14/2026
Work DescriptionCONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER.
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date04/08/2024 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing04/08/2024 Sample typeQuality Assurance
A brief description of the sampleRecycle Class 2 Aggregate Base The quantity of what the sample constitutes19507 grams
From where was the sample collectedJob Site First name of sampler or witnessed byIGNACIO
Last name of sampler or witnessed byARECHIGA Title of samplerTET
Telephone number of sampler5102077252 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Vallejo
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleClass 2Aggregate Base
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedJob site
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-04-08-18
DIME Test ID: 2024-04-08-18-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-04-09

Test Results


Is oversize material: No
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/08/2024
In-place wet density: 2.20
Highest adjust wet density: 2.21
% Moisture: 12.0 %
Optimum Moisture: 14.0 %
Relative compaction: 100
General comments (publicly viewable) (Max 1000 characters): Recycle Class 2 AB Vulcan

Test was verified on 4/9/2024 ✔