Summary for Test 2024-03-26-2-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994864 DEA: 050N74U4 EFIS: 0522000025 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-9.9/10.6 |
| Award Date | 07/10/2023 |
| Closeout Date | Not set |
| Work Description | SB 101 4D North San Ysidro to Olive Mill |
| Location Description | In Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing |
| QA Service Level | 1 (Verified on 08/21/2023) |
Sample Information
| Sample Taken Date | 03/26/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/02/2024 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A325 Type 1 HS Bolt 5/8 x 2 | The quantity of what the sample constitutes | 30 |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Andrew |
| Last name of sampler or witnessed by | Webster | Title of sampler | QA |
| Telephone number of sampler | 19254189838 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Saint Louis Screw and Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S90-012-24 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0176801 |
|---|---|---|---|
| Heat Number(s) | 10809130 20862560 219376 | Nut Mfg. Lot Number(s) | E156M1 |
| Washer Mfg. Lot Number(s) | 19382-219376 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | ASTM B695 Mechanical Galvanized |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | M5642 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2024-03-26-2
DIME Test ID: 2024-03-26-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-04-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 04/08/2024
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 37982 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 4/8/2024 ✔