Summary for Test 2024-04-02-2-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 994875 DEA: 101F1804 EFIS: 1016000077 |
---|---|
DIST-CO-RTE-PM | 10-SJ-4-R16.0/R19.4 |
Award Date | 09/20/2023 |
Closeout Date | Not set |
Work Description | BRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION |
QA Service Level | 1 (Verified on 06/14/2023) |
Sample Information
Sample Taken Date | 04/02/2024 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2024 |
Sample type | Quality Assurance | A brief description of the sample | #8 x 4'-3" |
The quantity of what the sample constitutes | 8 Samples from lot 1 and 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 916-767-3535 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar San Bernadino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-020-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 9001785, 4135333 |
Hoop Manufacturer Lot Number(s) | Lots 1 and 4 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #8 |
Diameter of Hoop | 4'-3" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel Arizona |
Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2024-04-02-2
DIME Test ID: 2024-04-02-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2024-04-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 04/08/2024
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | 8/25mm | 0.79 | 77572.90 | 98194 | Ok Necking | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 4/8/2024 ✔