Summary for Test 2024-04-03-34-4

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 995007
DEA: 061E7204
EFIS: 0622000092
DIST-CO-RTE-PM06-FRE-41-R27.0/R28.0
Award Date11/16/2023
Closeout Date09/08/2025
Work DescriptionWROUGHT IRON FENCE AND CONSTRUCT SOUND WALL.
Location DescriptionFRESNO COUNTY IN FRESNO AT VARIOUS LOCATIONS FROM DAKOTA AVENUE OVERCROSSING TO GETTYSBURG AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/27/2023)

Sample Information

Sample Taken Date04/03/2024 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2024
Sample typeQuality Assurance A brief description of the sample1x4, 3/8, Sand
The quantity of what the sample constitutes0-100yd3 From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of samplerSenior Materials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalPortland Fresno Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile at plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number172457 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-03-34
DIME Test ID: 2024-04-03-34-4
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2024-04-06

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 04/04/2024
Top sediment column reading (single primary size): 0.5 in
Cleanness value (single primary size): 86
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/6/2024