Summary for Test 2024-01-08-80-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
---|---|
DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
Award Date | 03/11/2020 |
Closeout Date | 06/05/2024 |
Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
Location Description | Junction of I-15 and SR-91 in Corona, CA |
QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
Sample Taken Date | 01/08/2024 | Sample Unique Key | 80 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/08/2024 |
Sample type | Department Acceptance | A brief description of the sample | Structural Backfill |
The quantity of what the sample constitutes | 15.0 kg | From where was the sample collected | Job Site |
First name of sampler or witnessed by | MaryAnna | Last name of sampler or witnessed by | Landaverde |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Soundwall 2192 - 1320 Cresta Rd, Freeway Side 91 WB to 15 NB | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-01-08-80
DIME Test ID: 2024-01-08-80-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-05
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: MaryAnna Landaverde
Date of test: 01/08/2024
Sum of Count or Density: 2779 g/cc
Average of Count or Density: 926 g/cc
Sum of Moisture Count: 308 g/cc
Average of Moisture Count: 103 g/cc
Count Ratio Density: 0.56
Count Ratio Moisture: 0.16
Calculated Percent Relative Compaction: 95.6 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 90%
Test was verified on 4/5/2024 ✔