Summary for Test 2024-03-19-26-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 03/19/2024 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/20/2024 |
Sample type | Department Acceptance | A brief description of the sample | 1" HMA-A-SP R25 1%LSM |
The quantity of what the sample constitutes | 4 BOXES OF HMA, 1 QT PG58-34M, 1 BAG AGG, 1 BAG RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | RIGOBERTO | Last name of sampler or witnessed by | ARROYO |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 143A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1 inch | Lot number | 3 |
Sublot number | 48 | HMA Mix Number | 300222 CPC R25 |
Test Details
DIME Sample ID: 2024-03-19-26
DIME Test ID: 2024-03-19-26-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-29
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 03/23/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 3147.5 g
Mass Loss: 140.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.10 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 3.80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/29/2024 ✔