Summary for Test 2024-02-24-10-4

Test performed: CTM 211-May 2010

Project Information

Project IdentifiersProject ID: 994247
DEA: 051H8604
EFIS: 0517000002
DIST-CO-RTE-PM05-SB-101-46.2/R52.3
Award Date02/01/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, PLACE HMA, RHMA-G, HMA-0, REPLACE MEDIAN BARRIER.
Location DescriptionSANTA BARBARA COUNTY NEAR GAVIOTA FROM 0.1 MILE NORTH OF GAVIOTA BEACH STATE PARK TO OLD COAST HIGHWAY
QA Service Level1 (Verified on 09/23/2022)

Sample Information

Sample Taken Date02/24/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeDepartment Acceptance A brief description of the sampleCalcined Bauxite
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byJohn Last name of sampler or witnessed byKopevil
Title of samplerSales Manager Telephone number of sampler
Laboratory sample identification24-0043, 24-0059 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFX Minerals Processing, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHigh Friction Surface Treatment Mgf. Lot Number(s)24-0614D
Batch NumberUnknown Mix NumberUnknown
Resin Binder TypeEpoxy Used for OverlayYes
Used for InlayNo

Test Details

DIME Sample ID: 2024-02-24-10
DIME Test ID: 2024-02-24-10-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2024-03-28

Test Results


How many revolutions are required?: 100 Revolution Test
Input Type: Measured
Tester's full name: Aristeo Flores
Date of test: 03/25/2024
Grading: D
Mass of sample: 5000 grams
Mass retained No. 4 sieve: no data
Mass retained No. 12 sieve: 4834 grams
Percent wear: 3 %
General comments (publicly viewable) (Max 1000 characters): Initial sample was insufficient to yield 5000g initial mass, so a second sample was requested. Arrived on 3/25/24

Test was verified on 3/28/2024