Summary for Test 2023-10-08-18-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 994609 DEA: 112N1194 EFIS: 1121000148 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-94-14.9/29.2 |
| Award Date | 05/18/2023 |
| Closeout Date | 05/06/2025 |
| Work Description | MICROSURFACING, RUMBLE STRIP, PAVEMENT MARKING, & SHOULDER BACKING. |
| Location Description | SAN DIEGO COUNTY NEAR JAMUL FROM JUNCTION ROUTE 54/94 TO 0.7 MILE EAST OF DULZURA CREEK |
| QA Service Level | 1 (Verified on 08/23/2023) |
Sample Information
| Sample Taken Date | 10/08/2023 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/27/2024 | Sample type | Quality Assurance |
| A brief description of the sample | Type III Micro-surfacing | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Source | First name of sampler or witnessed by | Michael |
| Last name of sampler or witnessed by | Stewart | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0209-S | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | VSSI | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Plant |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Micro-surfacing | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-10-08-18
DIME Test ID: 2023-10-08-18-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-03-28
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 03/29/2024
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1229.0 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 133.0 grams | 89 % | |||||
| 403 grams | ||||||
| 104.0 grams | 66 % | |||||
| 183.0 grams | 49 % | |||||
| 252.0 grams | 33 % | |||||
| 276.0 grams | 28 % | |||||
| 305.0 grams | 22 % | |||||
| 341.0 grams | 13.7 % | |||||
| 345.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): Test results are within specification limits.
Test was verified on 3/28/2024 ✔