Summary for Test 2024-03-05-47-3

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 994803
DEA: 043J0704
EFIS: 0415000077
DIST-CO-RTE-PM04-CC-80-10.1/13.5
Award Date03/10/2023
Closeout DateNot set
Work DescriptionRemove PCC and AC, place PCP and AC Resurfacing.
Location DescriptionConstruction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date03/05/2024 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeQuality Assurance A brief description of the sample1 x 4 PCC Aggregate +Sand
The quantity of what the sample constitutesone sample Two Bags From where was the sample collectedFabricator
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of samplerLab Technician Telephone number of sampler5102077252
Laboratory sample identificationRich_24_014 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard Mobile San Pablo Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBarrier

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002
The fabricator's/manufacturer's product name for the sampleload rapid set The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedContractors yard stockpile
Where the material sample would have been placed if not sampledyes Primary Aggregate Nominal Size1 inch
The concrete mix design number590MAC Lot number
Sublot number Aggregate Mix Number590MAC

Test Details

DIME Sample ID: 2024-03-05-47
DIME Test ID: 2024-03-05-47-3
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2024-03-27

Test Results


Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 03/06/2024
Wet weight of the sample: 2120.0000000000 grams
Dry weight of the sample: 1981.0000000000 grams
Weight of water in sample: 139.0000000000 grams
Percent moisture: 7.0 %
General comments (publicly viewable) (Max 1000 characters): Sample taken at Contractor Yard stockpile.

Test was verified on 3/27/2024