Summary for Test 2024-03-15-31-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 994962 DEA: 07357304 EFIS: 0719000062 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-6.6/13.1 |
Award Date | 04/27/2023 |
Closeout Date | Not set |
Work Description | REPLACE CONCRETE SLABS AND MEDIAN BARRIER, |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS, DOWNEY AND CITY OF COMMERCE FROM 0.2 MILE SOUTH OF ROUTE 5/605 SEPARATION TO 0.1 MILE NORT |
QA Service Level | 1 (Verified on 07/13/2023) |
Sample Information
Sample Taken Date | 03/15/2024 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/18/2024 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 and WCS |
The quantity of what the sample constitutes | 120 CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | onsite 605/ Washington blvd | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0025 and 91-33-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | mix CTS-65-EHI | |
The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | CTS-65-EHI | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-03-15-31
DIME Test ID: 2024-03-15-31-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2024-03-27
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 03/19/2024
Top sediment column reading (single primary size): 0.5 in
Cleanness value (single primary size): 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/27/2024 ✔