Summary for Test 2024-02-14-39-4
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 994772 DEA: 07385504 EFIS: 0722000147 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-91,110-Var |
| Award Date | 06/21/2023 |
| Closeout Date | 04/03/2025 |
| Work Description | PLACE ROCK BLANKETS, SLOPE PAVING, AND INSTALL FENCES AND GATES. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/24/2023) |
Sample Information
| Sample Taken Date | 02/14/2024 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/15/2024 |
| Sample type | Department Acceptance | A brief description of the sample | 3/8 & WCS |
| The quantity of what the sample constitutes | 30 cy | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
| Title of sampler | Telephone number of sampler | 2137924794 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Associated Ready Mix - Sun Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0025 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | Mix 5472471 | |
| The plant number | Sun Valley | A detailed description of where the material sample was collected | Stockpile @ Plant |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | 5472471 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-02-14-39
DIME Test ID: 2024-02-14-39-4
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-03-22
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 02/16/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.8
Sand reading (test 1): 4.3
Clay reading (test 2): 4.7
Sand reading (test 2): 4.1
Sand equivalent (test 1): 90
Sand equivalent (test 2): 88
Sand equivalent before temperature correction: 89
Sand equivalent after temperature correction: 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/22/2024 ✔