Summary for Test 2024-03-14-30-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 211080
DEA: 060V0304
DIST-CO-RTE-PM06-KER-99-7.3
Award DateNot set
Closeout Date04/04/2022
Work DescriptionGirder replacement and repairs due to bridge hit
Location DescriptionNear Bakersfield, from 7.3 miles N of the Rte 99/5 Jct to 6.1 miles S of the Rte 99/119 Jct at Ker 99-7.29
QA Service Level1 (Verified on 01/29/2016)

Sample Information

Sample Taken Date03/14/2024 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/15/2024
Sample typeDepartment Acceptance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes4 sets cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byFares Last name of sampler or witnessed byThwabah
Title of samplerASR Telephone number of sampler5593679003
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameViking Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNCT09064
The truck number from where the sample was collected117187984 The batch plant ticket number from where the sample was collectedAbut 8 piles
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedFrom the truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-03-14-30
DIME Test ID: 2024-03-14-30-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-03-21

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 03/21/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 50820 lb
Maximum load on cylinder 2: 48630 lb
Maximum load on cylinder 3: 49320 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4043.0 psi
Compressive strength of cylinder 2: 3868.7 psi
Compressive strength of cylinder 3: 3923.6 psi
Compressive strength (to nearest 10 psi): 3950 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2024