Summary for Test 2024-03-14-27-10
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 213457 DEA: 11430434 EFIS: 1118000197 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-8-12.9/14.6,14.9 |
| Award Date | 07/16/2022 |
| Closeout Date | 08/21/2025 |
| Work Description | HMA, STRUCTURAL BRIDGE, POLYESTER CONC OVERLAY, JPCP, & CONC BARRIER. |
| Location Description | SAN DIEGO COUNTY IN LA MESA AND EL CAJON FROM 0.1 MILE WEST OF GROSSMONT BOULEVARD OVERCROSSING TO WEST MAIN STREET OVERCROSSING AND AT MARSHALL AVENUE OVERHEAD |
| QA Service Level | 1 (Verified on 06/22/2018) |
Sample Information
| Sample Taken Date | 03/14/2024 | Sample Unique Key | 27 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/15/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 7815-PSU | Linked DIME Sample ID | 2024-03-14-26 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-03-14-27
DIME Test ID: 2024-03-14-27-10
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-03-26
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Daniel Smith / J Seymour
Date of test: 03/20/2024
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1372.4 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 29.1 grams | 98 % | |||||
| 284.9 grams | 79 % | |||||
| 550.9 grams | 60 % | |||||
| 782.5 grams | 43 % | |||||
| 975.9 grams | 29 % | |||||
| 1156.3 grams | 16 % | |||||
| 1282.3 grams | 7 % | |||||
| 1359.4 grams | 0.9 % | |||||
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 3/26/2024 ✔