Summary for Test 2024-02-22-11-2

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 994968
DEA: 120M82C4
EFIS: 1219000036
DIST-CO-RTE-PM12-ORA-1-7.9/10.5
Award Date12/13/2022
Closeout Date12/01/2025
Work DescriptionPlace RHMA-G and minor concrete and modify electrical system.
Location DescriptionIn Orange County In Laguna Beach, On State Route 1 (Also Known As Pacific Coast Highway Or Sr-1) From Ruby Street (Pm 7.9) To Ledroit
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date02/22/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/23/2024
Sample typeDepartment Acceptance A brief description of the sample3 1/4"x8" concrete core samples
The quantity of what the sample constitutes3 pcs From where was the sample collectedJob Site
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of sampler Telephone number of sampler7146990897
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans METS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete Core Detail descriptionconcrete core samples 3in x 8in
Structure namesPCH sidewalk deck Type of materialCore samples

Test Details

DIME Sample ID: 2024-02-22-11
DIME Test ID: 2024-02-22-11-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-03-20

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/29/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 3.33 in
Maximum load on cylinder 1: 42740 lb
Type of fracture pattern of cylinder 1: 2
Comment on any defect in either specimen or caps (Max 250 Characters): CORE D2 188.25, R13.5
Correction factor for cylinder 1: 1.00
Age of specimen: 1 days
Cross sectional area of cylinder 1: 8.71 in^2
Compressive strength of cylinder (to nearest 10 psi): 4910 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/20/2024